Generic placeholder image

Current Pharmaceutical Analysis

Editor-in-Chief

ISSN (Print): 1573-4129
ISSN (Online): 1875-676X

Research Article

A Comparative Chemometric Study for Quantitative Determination of Duloxetine Hydrochloride in the Presence of its Toxic Impurity 1-Naphthol

Author(s): Basma H. Anwar*, Nessreen S. Abdelhamid, Maimana A. Magdy and Ibrahim A. Naguib

Volume 16, Issue 8, 2020

Page: [1030 - 1036] Pages: 7

DOI: 10.2174/1573412915666190709093612

Price: $65

Abstract

Background: Duloxetine hydrochloride (DUL) is a serotonin-norepinephrine reuptake inhibitor. It is used for treating depression and anxiety. It is available in the market as a capsule called Cymbatex®, which is used for the treatment of depression. 1-naphthol is a potential impurity of DUL. It is hepatotoxic to humans and has potential toxicity to freshwater fish.

Objective: Duloxetine hydrochloride was determined in the presence of its toxic impurity 1-naphthol in raw material and in pharmaceutical dosage forms using three multivariate calibration chemometric methods.

Methods: Classical Least Squares (CLS), Partial Least-Squares (PLS) and linear support vector regression (SVR) were developed using UV spectral data. The three methods were compared among each other and the advantages and disadvantages were discussed. For good results, a two-factor four-level experimental design was used, resulting in a training set of 16 mixtures containing different ratios of each component. The test set consisting of nine mixtures was necessary to test the ability of the proposed methods to predict DUL in the presence of its impurity, 1-naphthol.

Results: The results show the success of the three developed methods to determine DUL in the presence of small levels of its toxic impurity with good accuracy and selectivity. The results of the dosage form were compared statistically to that of the reported HPLC method, with no significant difference in accuracy and precision.

Conclusion: The suggested calibration models are suitable for routine analysis of the drug in bulk and pharmaceutical dosage forms. Compared to the CLS and PLS models, the SVR model gives the best results regarding the accuracy with a lower prediction error and better generalization ability. However, the CLS and PLS models are found to be simpler and faster in usage and management.

Keywords: Duloxetine hydrochloride, 1-naphthol, classical least squares, partial least squares, linear support vector regression, chemometrics, UV-spectrophotometry.

Graphical Abstract
[1]
British Pharmacopeia; Her Majesty's Office: London, 2013.
[2]
Martindale, The complete drug reference pharmaceutical press, 2012.
[3]
Gerald, M. Cohen, Martyn T. Smith, Mechanisms of toxic injury to isolated hepatocytes by l-naphthol. Biochem. Pharmacol., 1984, 33(4), 543-549.
[http://dx.doi.org/10.1016/0006-2952(84)90305-8] [PMID: 6200119]
[4]
Tilak, K.S.; Mohanaranga, D. Rao and co-authers, Toxicity of carbaryl and 1-naphthol to four species of freshwater fish. J. Biosci., 1981, 3(4), 457-461.
[http://dx.doi.org/10.1007/BF02702634]
[5]
Mohammad Yunoos, D. Gowri Sankar and co-authers, Simple UV Spectrophotometric determination of duloxetine hydro-chloride in bulk and in pharmaceutical formulations. E-J. Chem., 2009, 7(3), 785-788.
[http://dx.doi.org/10.1155/2010/709176]
[6]
Kamila, M.M.; Mondal, N.; Ghosh, L.K. A validated UV spectrophotometric method for determination of duloxetine hydrochloride. Pharmazie, 2007, 62(6), 414-415.
[PMID: 17663186]
[7]
Usmangani, K.C. Development and validation of a stability-indicating RP-HPLC method for Duloxetine Hydrochloride in its bulk and tablet dosage form. Scientia. Pharmaceutica., 2010, 78, 857-868.
[8]
Sinha, V.R.; Anamika, R.K.; Bhinge, J.R. Stress degradation studies on duloxetine hydrochloride and development of an rphplcmethod for its determination in capsule formulation. J. Chromatogr. Sci., 2009, 47(7), 589-593.
[9]
Bhimanadhuni, C.N. Devala Rao Garikapati Krishna and co-authers, Development and validation of RP-HPLC method for determination of Duloxetine hydrochloride in bulk and dos-age form. Int. Curr. Pharm. J., 2012, 1(5), 98-102.
[http://dx.doi.org/10.3329/icpj.v1i5.10281]
[10]
Shahnawaz, S.; Siddiqui, Q.W.; Masroor, M.T.; Arora, V. Stability-indicating hptlc method for determination of duloxetine hydrochloride in bulk drug and tablet formulation. Chromatogr. Res. Int., 2011.
[11]
Dhaneshwar, S.S.; Deshpande, P.; Patil, M.; Vadnerkar, G.; Dhaneshwar, S.R. Development And Validation Of A Hptlc Method For Estimation Of Duloxetine Hydrochloride In Bulk Drug And In Tablet Dosage Form. Indian J. Pharm. Sci., 2008, 70(2), 233-236.
[http://dx.doi.org/10.4103/0250-474X.41463 PMID: 20046720]
[12]
Ammar, R.A.; Otaif, H.; Al-Warthan, A. Quantitative determination of duloxetine hydrochloride in pharmaceuticals and urine using prepared ion selective membrane electrode. Int. J. Electrochem. Sci., 2012, 2012(7), 4369-4380.
[13]
Raman, N.V.V.S.S.; Harikrishna, K.A.; Prasad, A.V.; Reddy, K.R.; Ramakrishna, K. Determination of duloxetine hydrochloride in the presence of process and degradation impurities by a validated stability-indicating RP-LC method. J. Pharm. Biomed. Anal., 2010, 51(4), 994-997.
[http://dx.doi.org/10.1016/j.jpba.2009.10.025 PMID: 20005658]
[14]
Navneet Kumar, D. Sangeetha and co-authers, Development and validation of a stability indicating RP-LC method for the estimation of process related impurities and degradation products of duloxetine hydrochloride and phthalic acid in du-loxetine hydrochloride delayed release capsules. J. Liq. Chromatogr. Relat. Technol., 2012, 35(7), 867-881.
[http://dx.doi.org/10.1080/10826076.2011.613141]
[15]
Q2 (R1). Validation of Analytical Procedures: Text and Meth-odology; ICH Harmonized Tripartite Guideline, 2005.
[16]
Richard, G. Brereton, Multilevel Multifactor Designs for Mul-tivariate Calibration. Analyst (Lond.), 1997, 122, 1521-1529.
[http://dx.doi.org/10.1039/a703654j]
[17]
Gasteiger, J. Handbook of Chemometrics; , 2003.
[18]
Wold, S. The collinearity problem in linear regression.the partial least squares (pls) approach to generalized inverses Society for Industrial and Applied Mathematics 1984, 5(3), 735-735.
[19]
Haaland, D.M. Thomas, Partial least-squares methods for spectral analyses. 1. Relation to other quantitative calibration methods and the extraction of qualitative information. Anal. Chem., 1988, 60, 1193-1202.
[http://dx.doi.org/10.1021/ac00162a020]
[20]
Brereton, R.G. Chemometrics: Data Analysis for the Laboratory and Chemical Plant. Chichester Wiley, 2003, p. 49.
[21]
Cristianini, N.; Shawe-Taylor, J. An Introduction to Support Vector Machines and Other Kernel-Based Learning Methods; Cambridge University Press: Cambridge, UK, 2000.
[http://dx.doi.org/10.1017/CBO9780511801389]
[22]
Suykens, J.A.K.; Gestel, T.V.; De Brabanter, J. Least Squares Support Vector Machines. J; World Scientific: Singapore, 1999.
[23]
S.R. Gunn, Support Vector Machines for Classification and Regression, Technical Report; University of Southampton: UK, 1998.
[24]
Parrella, F. Online Support Vector Regression., 2007.
[25]
Ibrahim, A. Naguib, Stability indicating analysis of bisacodyl by partial least squares regression, spectral residual augment-ed classical least squares and support vector regression chemometric models: A comparative study. Bull. Fac. Pharm. Cairo Univ., 2011, 49, 91-100.
[http://dx.doi.org/10.1016/j.bfopcu.2011.10.001]

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy