Investigation of the Pharmacokinetics of the ABCG2 Transporter Inhibitor Ko134 in Mice by a Newly Developed and Validated HPLC Method

ISSN: 1875-676X (Online)
ISSN: 1573-4129 (Print)

Volume 11, 4 Issues, 2015

Download PDF Flyer

Current Pharmaceutical Analysis

Aims & ScopeAbstracted/Indexed in

Submit Abstracts Online Submit Manuscripts Online

Anastasios Economou
Department of Chemistry
Laboratory of Analytical Chemistry
University of Athens

View Full Editorial Board

Subscribe Purchase Articles Order Reprints

Current: 0.719
5 - Year: 0.837

Investigation of the Pharmacokinetics of the ABCG2 Transporter Inhibitor Ko134 in Mice by a Newly Developed and Validated HPLC Method

Current Pharmaceutical Analysis, 10(1): 30-37.

Author(s): Anita Sztojkov-Ivanov, Orsolya Szolomajer-Csikos, Arpad Marki, Gabor K. Toth and Istvan Zupko.

Affiliation: Department of Pharmacodynamics and Biopharmacy, University of Szeged, H-6720 Szeged, Eotvos u. 6., Hungary.


Transporters belonging in the ATP-binding cassette (ABC) family are crucially involved in the determination of the pharmacokinetic behavior of xenobiotics and in the development of drug resistance. The targeting of these transporters has been accepted as a rational option via which to modify the absorption or distribution of pharmaceutical agents and to combat ABC-related inefficiency. Inhibitors of the breast cancer resistance protein (BCRP/ABCG2) multidrug transporter are of interest as chemosensitizers for clinical drug resistance, for improving the pharmacokinetics of substrate chemotherapeutic drugs, and in functional assays of BCRP activity for tailoring chemotherapy. In this study, a reversephase high-performance liquid chromatographic method was developed for the determination of a simplified fumitremorgin C analog, Ko134, a potent ABCG2 inhibitor, in murine serum. The assay involves a simple sample preparation step followed by chromatographic separation on a C8 reversed-phase analytical column. The calibration plots were linear over the range 0.1 to10 µg/ml (r > 0.99). The limits of detection and quantification were 10 ng/ml and 50 ng/ml, respectively. The validation results demonstrated that the method is precise, accurate and selective for the determination of Ko134 in mouse serum. The method was successfully applied to evaluate the pharmacokinetic parameters of Ko134 after different modes of administration in mice.


Drug administration, HPLC, Ko134, mouse serum, pharmacokinetics, validation.

Download Free Order Reprints Order Eprints Rights and Permissions

Article Details

Volume: 10
Issue Number: 1
First Page: 30
Last Page: 37
Page Count: 8
DOI: 10.2174/15734129113099990005

Related Journals

Webmaster Contact: Copyright © 2015 Bentham Science